Efficiency engineering tools
Turn equipment data into practical saving opportunities.
Build an equipment inventory and run focused LED, motor/VFD, and power-factor calculations before requesting a detailed audit.
Quick energy auditEquipment inventory
| Equipment name | Category | Rated power (kW) | Quantity | Hours/day | Days/year | Efficiency or condition | Annual energy | |
|---|---|---|---|---|---|---|---|---|
| 240 kWh/year |
Connected load0.1 kW
Annual energy240 kWh/year
Focused calculators
LED replacement
Annual energy6,600 kWh/year
Annual saving1,320
Simple payback0.9 years
Motor / VFD
Annual energy32,605 kWh/year
Annual saving6,521
Simple payback0.8 years
Power factor correction
Required capacitor bank63.5 kVAr
Planning calculations only. Verify operating profiles, measurements, equipment curves, harmonics, starting duty, voltage, tariffs, and site conditions before procurement.